SCHNEIDER VAMP57 SCHNEIDER V57F-3AAA3BCA-C PROTECTION RELAY
SCHNEIDER VAMP57 SCHNEIDER V57F-3AAA3BCA-C PROTECTION RELAY
SCHNEIDER VAMP57 SCHNEIDER V57F-3AAA3BCA-C PROTECTION RELAY
SCHNEIDER VAMP57 SCHNEIDER V57F-3AAA3BCA-C PROTECTION RELAY
SCHNEIDER VAMP57 SCHNEIDER V57F-3AAA3BCA-C PROTECTION RELAY
SCHNEIDER VAMP57 SCHNEIDER V57F-3AAA3BCA-C PROTECTION RELAY

SCHNEIDER VAMP57 SCHNEIDER V57F-3AAA3BCA-C PROTECTION RELAY

MOQ : 1 Unit

SCHNEIDER VAMP57 SCHNEIDER V57F-3AAA3BCA-C PROTECTION RELAY Specification

  • Contact Resistance
  • <100 m
  • Mechanical Life
  • >10,000,000 operations
  • Contact Form
  • 2 C/O (SPDT)
  • Contact Material
  • AgCdO (Silver Cadmium Oxide)
  • Coil Power
  • Not Applicable (microprocessor relay)
  • Dielectiric Strength
  • 2 kV, 50/60 Hz, for 1 min
  • Ambient Temperature
  • -25C to +55C
  • Working Temperature
  • -25C to +70C (storage)
  • Power Consumption
  • < 15 W
  • Coil Voltage
  • Not Applicable (electronic relay)
  • Protect Feature
  • Feeder, transformer, motor, and generator protection
  • Product Type
  • Protection Relay
  • Insulation Resistance
  • >10 M at 500 V DC
  • Theory
  • Microprocessor-based protection relay
  • Usage
  • Protection relay for electrical systems
  • Contact Load
  • 5A at 250V AC/30V DC (resistive)
  • Operate Time
  • Configurable, typically < 20 ms
  • Terminal Type
  • Screw Terminal / Plug-in connectors
  • Rated Voltage
  • 24-250 V AC/DC
  • Supply Terminal
  • Rear panel
  • Size
  • 96 x 96 mm front panel
  • Color
  • Grey/Black front panel with white frame
  • Dimension (L*W*H)
  • Approx. 110 x 100 x 110 mm
  • Weight
  • Approx. 1.5 kg
  • Memory Type
  • Non-volatile memory for event and fault recording
  • Model Number
  • VAMP57 / V57F-3AAA3BCA-C
  • Communication Protocols
  • RS485, Modbus, IEC 60870-5-103, DNP3, PROFIBUS
  • Mounting Type
  • Flush mounting panel type
  • Indication
  • LED indication for trip, alarm, and operation status
  • Firmware Update
  • Supported via communication port
  • Number of Outputs
  • 8 Relay Outputs
  • Trip Circuit Supervision
  • Provided
  • Number of Inputs
  • 8 Digital / 8 Analog (configurable)
  • Display Type
  • LCD with programmable push buttons
  • Compliance Standards
  • IEC 60255, CE Certified
  • Event Recording
  • Up to 300 events with timestamps
 

SCHNEIDER VAMP57 SCHNEIDER V57F-3AAA3BCA-C PROTECTION RELAY Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About SCHNEIDER VAMP57 SCHNEIDER V57F-3AAA3BCA-C PROTECTION RELAY



Experience incomparable security and magnificent operational control with the SCHNEIDER VAMP57 (V57F-3AAA3BCA-C) Protection Relay. Infused with inestimable precision through microprocessor-based technology, this relay offers instant checkout and seamless access to crucial system metrics via a vivid LCD display and programmable push buttons. It provides robust feeder, transformer, motor, and generator protection with user-friendly LED status indication and advanced event recording. Embrace modern integration with communication protocols like Modbus, PROFIBUS, and DNP3, backed by non-volatile memory and swift configurable operate times-truly a magnificent protection solution for critical electrical systems.

Versatile Use and Superior Application Adaptability

The SCHNEIDER VAMP57 PROTECTION RELAY is trusted by electrical engineers, utility companies, and industrial automation specialists. Designed for use with electrical switchgear and control panels, it is perfect for application on flush-mounted surfaces in substations, manufacturing plants, and distribution centers. Its adaptability makes it the relay of choice for safeguarding feeders, transformers, motors, and generators across diverse industries, ensuring continuous protection and operational reliability.


Optimized FOB Port, Domestic Reach, and Efficient Logistics

Facilitating packing & dispatch with efficiency, the SCHNEIDER VAMP57 relay ships via major Indian FOB ports, ensuring rapid fulfillment. It is available for prompt supply throughout the main domestic market, including industrial hubs across India. Packaging is secure and tailored to protect the relay in transit. With robust supply ability and competitive proposal amounts, orders are processed swiftly for timely delivery, supporting seamless project planning and inventory management.


FAQ's of SCHNEIDER VAMP57 SCHNEIDER V57F-3AAA3BCA-C PROTECTION RELAY:


Q: How does the SCHNEIDER VAMP57 relay enhance protection in electrical systems?

A: The SCHNEIDER VAMP57 provides advanced protection for feeders, transformers, motors, and generators, featuring rapid response times, configurable operation, and precise event recording to help prevent equipment failure and maintain safety across electrical infrastructures.

Q: What protocols and connectivity options are available with this relay?

A: This relay supports a wide range of communication protocols including RS485, Modbus, IEC 60870-5-103, DNP3, and PROFIBUS, allowing seamless integration with various automation and monitoring systems.

Q: Where can the SCHNEIDER VAMP57 be installed for optimal performance?

A: It is designed for flush panel mounting, making it suitable for installation in electrical switchgear compartments, substation control panels, and industrial process automation boards.

Q: What is the process for updating the firmware on this protection relay?

A: Firmware updates are easily performed via the communication port, allowing users to ensure their device remains updated with the latest features and security enhancements.

Q: What are the benefits of its event recording capability?

A: With the ability to record up to 300 events with timestamps, this relay enables detailed fault analysis and effective troubleshooting, promoting fast system recovery and reducing downtime.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Protection Relay Category

MICOM P127 SCHNEIDER MICOM P127 PROTECTION RELAY SCHNEIDER P127BA0Z112FE0

MICOM P127 SCHNEIDER MICOM P127 PROTECTION RELAY SCHNEIDER P127BA0Z112FE0

Minimum Order Quantity : 1 Unit

Dielectiric Strength : 2 kV/1 min between contacts

Size : Other, Standard relay module

Usage : Protection relay for electrical networks

Dimension (L*W*H) : 242 mm x 172 mm x 64 mm

Insulation Resistance : >100 M at 500 VDC

SCHNEIDER MICOM P141 PROTECTION RELAY SCHNEIDER P14131RA7M0B28L

SCHNEIDER MICOM P141 PROTECTION RELAY SCHNEIDER P14131RA7M0B28L

Minimum Order Quantity : 1 Unit

Dielectiric Strength : 2 kV, 50 Hz, 1 min

Size : Other, 19 inch Rack Mountable

Usage : Protection Relay for electrical systems

Dimension (L*W*H) : 272 mm x 212 mm x 141 mm

Insulation Resistance : >100 M at 500V DC

M Safety Relay Module 24VDC Part No. 2986012

M Safety Relay Module 24VDC Part No. 2986012

Minimum Order Quantity : 1 Unit

Dielectiric Strength : 2.5 kV AC, 1 min

Size : Other, Standard DIN module size

Usage : Industrial safety relay applications

Dimension (L*W*H) : Approx. 100 x 85 x 45 mm

Insulation Resistance : >100 M (500V DC)

BASLER BE1-64F BASLER BE164F FIELD GROUND RELAY

BASLER BE1-64F BASLER BE164F FIELD GROUND RELAY

Minimum Order Quantity : 1 Unit

Dielectiric Strength : 2000V AC for 1 min

Size : Other, Standard Panel Mount

Usage : Field Ground Protection for Generators and Transformers

Dimension (L*W*H) : 224mm x 110mm x 220mm

Insulation Resistance : >100 M @ 500V DC